Nominal Current Range Ipn (Apn)
|
Power Supply Range (V)
|
Global Accuracy @ +25”ĘC, % of Ipn
|
Bandwidth (kHz)
|
Mounting
|
Technology
|
Series
|
|
0.25 - 200
|
+/- 12...15
|
0.4 - 0.9%
|
DC - 150
|
PCB
|
C/L
|
LA 25-200 -P
|
|
100 - 1000
|
+/- 15
|
1 - 1.35%
|
DC - 50
|
Panel
|
O/L
|
HTA Traction
|
|
200- 500
|
+/- 12...24
|
0.6 - 0.9%
|
DC - 100
|
Panel
|
C/L
|
LA 205 / 305 -S/ -T Traction
|
|
200 - 500
|
+/- 24
|
1%
|
DC - 100
|
Split core
|
C/L
|
LA 200 / 500-SD
|
|
200 - 2000
|
+/- 12...24
|
0.2 - 0.4%
|
DC - 150
|
Panel
|
C/L
|
LF Traction
|
|
300 - 400
|
+/-15
|
0.7 - 1 %
|
DC - 50
|
Panel
|
C/L
|
LAC 300-S
|
|
350 - 500
|
+/- 15...+/- 24
|
0.5 - 0.6%
|
DC - 100
|
Panel
|
C/L
|
LTC 350 - 500
|
|
250 - 4400
|
+/- 15..60
...+24
|
0.2 - 0.8%
|
DC - 150
|
Panel
|
C/L
|
LT Traction
|
|
500 -1000
|
+/- 15... +/- 24
|
0.4 - 0.7%
|
DC - 100
|
Panel
|
C/L
|
LTC 600 - 1000
|
|
500 - 3000
|
+/- 15
|
2.8%
|
DC - 10
|
Panel
|
O/L
|
HTC
|
|
1000
|
+/- 15
|
1.2%
|
DC - 10
|
Panel
|
O/L
|
HAR
|
|
4000 - 20000
|
+/- 15
|
1%
|
DC - 3
|
Panel
|
O/L
|
HAZ
|
|
|
|
|
|
|
|
|
|
<20 A AC on
<3000 A DC
|
+/- 15
|
<5 %
|
10 - 3000Hz
|
Panel
|
Rogowski
|
RA Interference Current Measurement
|
|
|
|
|
|
|
|
|
|
+/- 2
|
+/- 15
|
2.5 %
|
5
|
Panel
|
Fluxgate C
|
CD Differential Current Measurement
|
Data is for general information only, Please refer to specific
data sheet for each product.
Current measurement in trackside railway applications
|
Nominal Current Range Ipn (A)
|
Power Supply Range (V)
|
Global Accuracy @ +25”ĘC, % of Ipn
|
Bandwidth (kHz)
|
Mounting
|
Technology
|
Series
|
|
10 - 30
|
0...+24
|
1
|
DC...1
|
Panel / Rail
DN
|
C/L
|
Points Conditions Monitoring (PCM)
|
Voltage measurement
in traction on-board applications
With built-in resistor R1
|
Nominal Voltage Range Vpn
|
Power Supply Range (V)
|
Global Accuracy @ +25”ĘC, % of Ipn
|
Bandwidth (kHz)
|
Mounting
|
Technology
|
Series
|
|
50 -2000
|
+/- 12...24
|
0.7
|
<13
|
Panel
|
Isolation Amplifier
|
AV 100-Voltage
|
|
50 - 2000
|
+/- 15...24
|
0.7 - 1.2
|
<10
|
Panel
|
C/L
|
LV 100-Voltage 1
|
|
85 - 1400
|
+/- 15...24
|
<0.375
|
<300 - 800
|
Panel
|
Fluxgate C
|
CV 3-Voltage
|
|
200 - 1200
|
+/- 12...15
|
0.8 - 0.9
|
<10
|
Panel
|
C/L
|
LV 25-Voltage
|
|
200 - 6400
|
+/- 15...24
|
0.8 - 2.5
|
<1
|
Panel
|
C/L
|
LV 200-AW/2/Voltage
|
|
2121 - 4242
|
+/- 15 & +/- 24
|
<1.4
|
<21
|
Panel
|
Fluxgate C
|
CV 4-Voltage
|
|
2500 - 4000
|
+/- 15...24
|
0.2 - 0.8
|
<10
|
Panel
|
C/L
|
LV 100-Voltage 2
|
Without resistor R1
|
Nominal Voltage Range Ipn (Vpn)
|
Power Supply Range (V)
|
Global Accuracy @ +25”ĘC, % of Ipn
|
Bandwidth (kHz)
|
Mounting
|
Technology
|
Series
|
|
10 mA
(10 - 500V)
|
+/- 12...15
|
0.8 - 1
|
<10
|
PCB
|
C/L
|
LV 25-P
|
|
10 - 210 mA
(100 - 2500V)
|
+/- 12...24
|
0.7
|
<10
|
Panel
|
C/L
|
LV 100
|
|
20 mA
(100 - 2500V)
|
+/- 15...24
|
0.6
|
<6
|
Panel
|
C/L
|
LV 200-AW/2
|
|